§ 15-2012. HEIGHTS AND HEIGHT EXCEPTIONS.  


Latest version.
  • A.

    Applicability. The standards of this section apply to:

    1.

    New development or structures; or

    2.

    New equipment that is added to serve existing buildings.

    B.

    General Standards. The structures listed in the following table may exceed the maximum permitted building height for the district in which they are located, subject to the limitations stated in the table and further provided that no portion of a structure in excess of the building height limit may be used for sleeping quarters or advertising and all heights shall comply with any operative Airport Plan.

    TABLE 15-2012-B: ALLOWED PROJECTIONS ABOVE HEIGHT LIMITS
    Structures Allowed Above the Height Limit Maximum Coverage, Locational Restrictions Maximum Vertical Projection Above the Height Limit (ft)
    Skylights No limitation 1
    Solar panels, and other energy production facilities located on a rooftop No limitation 10
    Parapets No limitation 4
    Chimneys
    Elevator and stair towers
    Rooftop open space features such as sunshade and windscreen devices, open trellises, and landscaping (for multi-family and non-residential buildings only)
    Flagpoles
    10% of roof area 16 (if no height limit in the underlying district, 35)
    Decorative features such as spires, bell towers, domes, cupolas, obelisks, clock towers, and monuments (attached or detached) 10% of roof area Residential: 6
    Non-Residential: 20
    Fire escapes, catwalks, and open railings required by law Per Building Code Per Building Code
    Radio towers Refer to Section 15-2759, Telecommunications and Wireless Facilities
    Water tanks
    Windmills
    Industrial structures where the manufacturing process requires a greater height
    25% of the area of the lot, or 10% of the roof area of all on-site structures, whichever is less. Must be located at least 25 ft. from any lot line. 100. May exceed 100 with the approval of a Conditional Use Permit. Public noticing shall be eight times the height of the structure measured in ft.
    Building-mounted telecommunications facilities, antennas, and microwave equipment Subject to the provisions of Section 15-2759, Telecommunications and Wireless Facilities

     

    C.

    Building height shall be measured as put forth in Section 15-305, Measuring Height.

(Added Ord. 2015-39, § 1, eff. 1-9-16).